CJX2-N AC Reversing Contactor, 3 Phase Reversing Contactor 3P 4P 9A ~ 95A AC-3 AC-1
Product Details
| Peringkat arus utama: | 9-95A | Jenis listrik: | AC, AC / DC |
|---|---|---|---|
| Tegangan rating rangkaian utama: | 600V, 220V, 380V, 110V, 24V | Jumlah tiang: | 3,4 |
| Tahap: | 3,1Phase | frekuensi: | 50 / 60Hz |
| Nama Produk: | Ac Contactor CJX2N-D09,3 tiang Ac Contactor | Populer saat ini: | 95A |
| Standar: | IEC60947, EN / IEC60947-4-1 | ||
| Menyoroti |
saklar kontaktor ac,kontaktor ac pusat |
||
Product Description
ciri
• Kisaran saat ini 09 ~ 95A;
• AC, koil kontrol DC adalah opsional (koil DC ke 38A);
• Berbagai jenis starter tersedia: kontaktor start motor standar, kontaktor reversibel, starter star-delta, starter autotransformer, dll.
• Koneksi opsional: koneksi baut (09 ~ 620A), koneksi terminal dering (09 ~ 38A), koneksi terminal (40 ~ 65A), nyaman untuk instalasi pelanggan;
• Sertifikasi Produk: CCC, CE, CCS;
Keuntungan
• Instalasi kompak
> Kontaktor ke 38A dan komponen perlindungan hanya selebar 45mm
> Instalasi penekan lonjakan tidak memerlukan alat dan dapat dimasukkan langsung ke kontaktor tanpa mengambil lebih banyak ruang
> Kontaktor yang dapat dibalik hanya selebar 90mm, penguncian mekanis tidak membutuhkan ruang ekstra, pemasangan hampir tidak memerlukan waktu
> Komponen starter menyediakan modul pra-kabel untuk perakitan cepat dan mudah
• Sangat terintegrasi
> ke 100A integrasi kontaktor 1 biasanya terbuka / 1 kontak bantu biasanya tertutup
> Koil DC dengan dioda penekan dua arah bawaan
> Grup kontaktor reversibel dengan dioda penindasan dua arah bawaan
• Aman dan andal
> Rangkaian utama dan sirkuit kontrol dari komponen kontrol dan perlindungan dibedakan secara jelas
> Desain kontak cermin yang memenuhi standar keselamatan, memastikan 10 juta tindakan yang dapat diandalkan
> Tutup pelindung mencegah kontak kontaktor yang tidak disengaja
• kualitas luar biasa
> Kumparan DC memiliki berbagai tegangan kontrol (0.7 ~ 1.25Uc)
> Tahan gempa yang kuat
> kebisingan yang lebih rendah
> Peningkatan kekuatan terminal
CJX2 40-65A:
> Torsi permanen, instalasi andal
> Hemat dan hemat ruang
> Mudah dipasang, menghemat waktu
> Mudah dirawat dan menghemat biaya
| Product Series | NC |
|---|---|
| product name | Kontaktor |
| product type | Reversing contactor |
| Product short name | CJX2-N |
| Contactor application area | Applied to AC loads with a power factor greater than or equal to 0.95 Squirrel cage motor for switching on and off normal start |
| Use category | AC-1 AC-3 |
| Equipment introduction | Pre-assembled with reversible power supply busbar |
| Number of poles | 3P |
| Power pole contact composition | 3 NO |
| Rated working voltage [Ue] | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC |
| Rated operating current [Ie] | 25 A 60 °C) on <= 440 V AC AC-3 Applicable power circuit 40 A 60 °C) on <= 440 V AC AC-1 for power supply circuits |
| Motor power (kW) | 5.5 kW on 220...230 V AC 50/60 Hz 11 kW on 380...400 V AC 50/60 Hz 11 kW on 415...440 V AC 50/60 Hz 15 kW on 500 V AC 50/60 Hz 15 kW on 660...690 V AC 50/60 Hz |
| Motor power HP (UL / CSA) | 3 hp on 230/240 V AC 50/60 Hz for 1-phase motors 5 hp on 200/208 V AC 50/60 Hz for 3-phase motors 2 hp on 115 V AC 50/60 Hz for 1-phase motors 7.5 hp on 230/240 V AC 50/60 Hz for 3-phase motors 15 hp on 460/480 V AC 50/60 Hz for 3-phase motors 20 hp on 575/600 V AC 50/60 Hz for 3-phase motors |
| Control loop characteristics | AC on 50/60 Hz |
| Control loop voltage | 220 V AC 50/60 Hz |
| Auxiliary contact type | 1 NO + 1 NC |
| Rated impulse withstand voltage [Uimp] | 6 kV in accordance with IEC 60947 |
| Overvoltage category | III |
| Conventional heating current [Ith] | 10 A on <60 °C for signal circuit 40 A on <60 °C for power supply circuit |
| Rated turn-on capability [Irms] | 140 A AC suitable signal circuit in accordance with IEC 60947-5-1 250 A DC suitable signal loop in accordance with IEC 60947-5-1 450 A on 440 V applicable power supply circuit in accordance with IEC 60947 |
| Rated breaking capacity | 450 A on 440 V applicable power supply circuit in accordance with IEC 60947 |
| Rated short-time withstand current [Icw] | 50 A on <40 °C - 10 minutes for power circuit 120 A on <40 °C - 1 minute for power circuit 240 A on <40 °C - 10 s for power supply circuit 380 A on <40 °C - 1 s for power supply circuit 100 A - 1 s for signal circuits 120 A - 500 ms Applicable signal loop 140 A - 100 ms for signal circuits |
| Fuses used with relays | 10 A gG Applicable signal circuit in accordance with IEC 60947-5-1 63 A gG on ...<= 690 V with type 1 for power supply circuit 40 A gG on ...<= 690 V with type 2 for power supply circuit |
| Average impedance | 2 mΩ - Ith 40 A 50 Hz for power supply circuits |
| Rated insulation voltage [Ui] | 690 V complies with IEC 60947-4-1 600 V CSA certification 600 V UL certification 690 V in accordance with IEC 60947-1 |
| Electrical life | 1.65 kA2.s 25 A AC-3 Ue condition <= 440 V 1.4 kA2.s 40 A AC-1 Ue condition <= 440 V |
| Power consumption per pole | 1.25 W AC-3 3.2 W AC-1 |
| Safety cover | band |
| Interlock type | mechanical |
| Installation method | Rail mounting Base plate installation |
| Standards compliant | EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 EN 60947-4-1 |
| certified product | CCC |
| Wiring ability | Control circuit: Bolt fastening 1 Cable 1...4 mm2 cord without Control circuit: Bolt fastening 2 Cable 1...4 mm2 cord without Control circuit: Bolt fastening 1 Cable 1...4 mm2 cord Control circuit: Bolt fastening 2 Cable 1...2.5 mm2 cord Control circuit: Bolt fastening 1 Cable 1...4 mm2 hard wire without Control circuit: Bolt fastening 2 Cable 1...4 mm2 hard wire without Power circuit: Bolt fastening 1 Cable 2.5...10 mm2 cord without Power circuit: Bolt fastening 2 Cable 2.5...10 mm2 cord without Power circuit: Bolt tightening 1 Cable 1...10 mm2 cord Power circuit: bolt fastening 2 cable 1.5...6 mm2 cord Power circuit: bolt fastening 1 cable 1.5...10 mm2 hard wire without Power circuit: Bolt fastening 2 Cable 2.5...10 mm2 hard wire without |
| Tightening torque | Control circuit: 1.7 Nm Screwdriver with bolt Ø 6 flat Control circuit: 1.7 Nm Screwdriver with No 2 Phillips screw Power circuit: 2.5 Nm Screwdriver with bolt Ø 6 flat Power circuit: 2.5 Nm Screwdriver with No 2 Phillips screw |
| Action time | 12...22 ms closed 4...19 ms break |
| Safety and reliability | B10d = 1369863 Contactors with nominal load compliance in accordance with EN/ISO 13849-1 B10d = 20000000 mechanical load contactors comply with EN/ISO 13849-1 |
| Mechanical life | 15 kA2.s |
| Maximum operating frequency | 3600 times / hour on ... <60 °C |
| Surge suppression module | No built-in surge suppression module |
|---|---|
| Control voltage limit | Release: 0.3...0.6 Uc on 50/60 Hz 60 °C) Operation: 0.8...1.1 Uc on 50 Hz 60 °C) Operation: 0.85...1.1 Uc on ... 60 Hz 60 °C) |
| (~50Hz pull-in) power consumption (VA) | 70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
| (~50Hz hold) power consumption (VA) | 7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
| Heat dissipation | 2...3 W on 50/60 Hz |
| Auxiliary contact type | Type mechanical connection 1 NO + 1 NC in accordance with IEC 60947-5-1 Type mirrored to the main contact state 1 NC in accordance with IEC 60947-4-1 |
| Signal loop frequency | 25...400 Hz |
| Minimum switching current [Imin] | 5 mA suitable signal loop |
| Minimum switching voltage | 17 V for signal circuit |
| No overlap time | 1.5 ms between power loss NC and NO contact 1.5 ms between the NC and NO contacts |
| Insulation resistance | > 10 MΩ for signal circuits |
| IP protection level | IP20 front panel complies with IEC 60529 |
|---|---|
| Protective measures | TH conforms to IEC 60068-2-30 |
| Pollution level | 3 |
| Operating temperature | -5...60 °C |
| Storage ambient temperature | -60...80 °C |
| Ambient air temperature | -40...70 °C (allowed under Uc) |
| Working elevation | 3000 m without |
| Refractory and resistant to abnormal high temperatures | 850 °C in accordance with IEC 60695-2-1 |
| Flame retardant | V1 complies with UL 94 |
| Shock and vibration resistance | Seismic performance contacts open: 2 gn (5...300 Hz) Seismic performance contact closure: 4 gn (5...300 Hz) Impact resistance contact closure: 15 gn (11ms) Impact resistance contacts open: 8 gn (11ms) |
| height | 85 mm |
| width | 90 mm |
| depth | 92 mm |
| product weight | 0.787 kg |


Product Highlights
Chint CJX2-N AC Reversing Contactor 3P, 4P 9A ~ 95A 1810, 2510, 3210, 6511, AC-3 AC-1 Koil Tegangan 24V, 110V, 230V, 380V ciri • Kisaran saat ini 09 ~ 95A; • AC, koil kontrol DC adalah opsional (koil DC ke 38A); • Berbagai jenis starter tersedia: kontaktor start motor standar, kontaktor reversibel, ...
Siap Untuk Menginstal Jenis MCB Kotak Distribusi RCCB RCBO Untuk Rumah AC220 ~ 240V 63A Masuk
Ready to Install Type A Distribution Box with MCB, RCCB or RCBO Custom for Home Use AC220~240V Incoming 63A Material: ABS/PC Color: Grey White/Transparent Cover Application: Power Distributing Type: Distribution Box Electrical Boxes Installation Type: Surface Type/ Flush Type Standard: IEC60439-3 ...
6kA Pemutus Sirkuit Listrik, 2 Pemutus Sirkuit Tiang 1 ~ 63A 1P 3P 4P 1P + N
Osmart OSMC32N 6kA Schneider Electric Miniature Circuit Breaker 1~63A, 1P,2P,3P,4P,1P+N in compliance with IEC-EN60898 Osmart OSMC32N MCBs Schneider Electric Original Made In China Miniature Circuit Breakers up to 63 A characteristic * Product standard: GB10963.1/IEC 60898 * Product Certification: ...
Single RGB Inflatable Led Light Mengubah Warna, Acara Lighting Balon Led Lantern Lights
Single RGB LED lighting Source Muse™130C Events Lighting Balloon with 72w/96w Color Changing LED 1. General features Smart Color LED changer balloon light Muse-Color Dual White, Muse-Color RGB+CCTpowered by LED bulb 72w, max 96w Print your company logo or event name on our giant advertising balloon ...
Pengaturan Digital Modular Timing Relay AC DC 12V 24V
RT8-K Digital Setting Timer Relay AC DC 12V 24V 220V 230V Multifunction Time Delay on off Relay General Multifunctional time relay with digital settings can be used for industrial equipment, lighting control, heating element control, motor and fan control. It has four delay modes and the delay range ...
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.