Mengirim pesan
Wuxi Fenigal Sains & Teknologi Co, Ltd

Produsen dan Pemasok untuk Produk Listrik & Penerangan

Tentang kita
Wisata pabrik
Kontrol kualitas
Hubungi kami
Rumah ProdukRelay Kontrol Otomatisasi

CJX2-N AC Reversing Contactor, 3 Phase Reversing Contactor 3P 4P 9A ~ 95A AC-3 AC-1

CJX2-N AC Reversing Contactor, 3 Phase Reversing Contactor 3P 4P 9A ~ 95A AC-3 AC-1

  • CJX2-N AC Reversing Contactor, 3 Phase Reversing Contactor 3P 4P 9A ~ 95A AC-3 AC-1
  • CJX2-N AC Reversing Contactor, 3 Phase Reversing Contactor 3P 4P 9A ~ 95A AC-3 AC-1
  • CJX2-N AC Reversing Contactor, 3 Phase Reversing Contactor 3P 4P 9A ~ 95A AC-3 AC-1
  • CJX2-N AC Reversing Contactor, 3 Phase Reversing Contactor 3P 4P 9A ~ 95A AC-3 AC-1
CJX2-N AC Reversing Contactor, 3 Phase Reversing Contactor 3P 4P 9A ~ 95A AC-3 AC-1
Detail produk:
Tempat asal: Cina
Nama merek: Chint
Sertifikasi: CE,CCC,CB etc.
Nomor model: CJX2-N
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: 1 unit
Harga: USD15~USD138
Kemasan rincian: Standar ekspor karton
Waktu pengiriman: 5-8 hari kerja atau negosiasi pesanan massal
Syarat-syarat pembayaran: T/T, Western Union
Menyediakan kemampuan: 1.000 pcs / bulan
Kontak
Detil Deskripsi produk
Peringkat arus utama: 9-95A Jenis listrik: AC, AC / DC
Tegangan rating rangkaian utama: 600V, 220V, 380V, 110V, 24V Jumlah tiang: 3,4
Tahap: 3,1Phase frekuensi: 50 / 60Hz
Nama Produk: Ac Contactor CJX2N-D09,3 tiang Ac Contactor Populer saat ini: 95A
Standar: IEC60947, EN / IEC60947-4-1
Cahaya Tinggi:

saklar kontaktor ac

,

kontaktor ac pusat

Chint CJX2-N AC Reversing Contactor 3P, 4P 9A ~ 95A 1810, 2510, 3210, 6511, AC-3 AC-1 Koil Tegangan 24V, 110V, 230V, 380V

ciri
• Kisaran saat ini 09 ~ 95A;
• AC, koil kontrol DC adalah opsional (koil DC ke 38A);
• Berbagai jenis starter tersedia: kontaktor start motor standar, kontaktor reversibel, starter star-delta, starter autotransformer, dll.
• Koneksi opsional: koneksi baut (09 ~ 620A), koneksi terminal dering (09 ~ 38A), koneksi terminal (40 ~ 65A), nyaman untuk instalasi pelanggan;
• Sertifikasi Produk: CCC, CE, CCS;


Keuntungan
• Instalasi kompak
> Kontaktor ke 38A dan komponen perlindungan hanya selebar 45mm
> Instalasi penekan lonjakan tidak memerlukan alat dan dapat dimasukkan langsung ke kontaktor tanpa mengambil lebih banyak ruang
> Kontaktor yang dapat dibalik hanya selebar 90mm, penguncian mekanis tidak membutuhkan ruang ekstra, pemasangan hampir tidak memerlukan waktu
> Komponen starter menyediakan modul pra-kabel untuk perakitan cepat dan mudah
• Sangat terintegrasi
> ke 100A integrasi kontaktor 1 biasanya terbuka / 1 kontak bantu biasanya tertutup
> Koil DC dengan dioda penekan dua arah bawaan
> Grup kontaktor reversibel dengan dioda penindasan dua arah bawaan
• Aman dan andal
> Rangkaian utama dan sirkuit kontrol dari komponen kontrol dan perlindungan dibedakan secara jelas
> Desain kontak cermin yang memenuhi standar keselamatan, memastikan 10 juta tindakan yang dapat diandalkan
> Tutup pelindung mencegah kontak kontaktor yang tidak disengaja
• kualitas luar biasa
> Kumparan DC memiliki berbagai tegangan kontrol (0.7 ~ 1.25Uc)
> Tahan gempa yang kuat
> kebisingan yang lebih rendah
> Peningkatan kekuatan terminal
CJX2 40-65A:
> Torsi permanen, instalasi andal
> Hemat dan hemat ruang
> Mudah dipasang, menghemat waktu
> Mudah dirawat dan menghemat biaya

main information
Product Series
NC
product name
Kontaktor
product type
Reversing contactor
Product short name
CJX2-N
Contactor application area
Applied to AC loads with a power factor greater than or equal to 0.95
Squirrel cage motor for switching on and off normal start
Use category
AC-1
AC-3
Equipment introduction
Pre-assembled with reversible power supply busbar
Number of poles
3P
Power pole contact composition
3 NO
Rated working voltage [Ue]
Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
Rated operating current [Ie]
25 A 60 °C) on <= 440 V AC AC-3 Applicable power circuit
40 A 60 °C) on <= 440 V AC AC-1 for power supply circuits
Motor power (kW)
5.5 kW on 220...230 V AC 50/60 Hz
11 kW on 380...400 V AC 50/60 Hz
11 kW on 415...440 V AC 50/60 Hz
15 kW on 500 V AC 50/60 Hz
15 kW on 660...690 V AC 50/60 Hz
Motor power HP (UL / CSA)
3 hp on 230/240 V AC 50/60 Hz for 1-phase motors
5 hp on 200/208 V AC 50/60 Hz for 3-phase motors
2 hp on 115 V AC 50/60 Hz for 1-phase motors
7.5 hp on 230/240 V AC 50/60 Hz for 3-phase motors
15 hp on 460/480 V AC 50/60 Hz for 3-phase motors
20 hp on 575/600 V AC 50/60 Hz for 3-phase motors
Control loop characteristics
AC on 50/60 Hz
Control loop voltage
220 V AC 50/60 Hz
Auxiliary contact type
1 NO + 1 NC
Rated impulse withstand voltage [Uimp]
6 kV in accordance with IEC 60947
Overvoltage category
III
Conventional heating current [Ith]
10 A on <60 °C for signal circuit
40 A on <60 °C for power supply circuit
Rated turn-on capability [Irms]
140 A AC suitable signal circuit in accordance with IEC 60947-5-1
250 A DC suitable signal loop in accordance with IEC 60947-5-1
450 A on 440 V applicable power supply circuit in accordance with IEC 60947
Rated breaking capacity
450 A on 440 V applicable power supply circuit in accordance with IEC 60947
Rated short-time withstand current [Icw]
50 A on <40 °C - 10 minutes for power circuit
120 A on <40 °C - 1 minute for power circuit
240 A on <40 °C - 10 s for power supply circuit
380 A on <40 °C - 1 s for power supply circuit
100 A - 1 s for signal circuits
120 A - 500 ms Applicable signal loop
140 A - 100 ms for signal circuits
Fuses used with relays
10 A gG Applicable signal circuit in accordance with IEC 60947-5-1
63 A gG on ...<= 690 V with type 1 for power supply circuit
40 A gG on ...<= 690 V with type 2 for power supply circuit
Average impedance
2 mΩ - Ith 40 A 50 Hz for power supply circuits
Rated insulation voltage [Ui]
690 V complies with IEC 60947-4-1
600 V CSA certification
600 V UL certification
690 V in accordance with IEC 60947-1
Electrical life
1.65 kA2.s 25 A AC-3 Ue condition <= 440 V
1.4 kA2.s 40 A AC-1 Ue condition <= 440 V
Power consumption per pole
1.25 W AC-3
3.2 W AC-1
Safety cover
band
Interlock type
mechanical
Installation method
Rail mounting
Base plate installation
Standards compliant
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
EN 60947-4-1
certified product
CCC
Wiring ability
Control circuit: Bolt fastening 1 Cable 1...4 mm2 cord without
Control circuit: Bolt fastening 2 Cable 1...4 mm2 cord without
Control circuit: Bolt fastening 1 Cable 1...4 mm2 cord
Control circuit: Bolt fastening 2 Cable 1...2.5 mm2 cord
Control circuit: Bolt fastening 1 Cable 1...4 mm2 hard wire without
Control circuit: Bolt fastening 2 Cable 1...4 mm2 hard wire without
Power circuit: Bolt fastening 1 Cable 2.5...10 mm2 cord without
Power circuit: Bolt fastening 2 Cable 2.5...10 mm2 cord without
Power circuit: Bolt tightening 1 Cable 1...10 mm2 cord
Power circuit: bolt fastening 2 cable 1.5...6 mm2 cord
Power circuit: bolt fastening 1 cable 1.5...10 mm2 hard wire without
Power circuit: Bolt fastening 2 Cable 2.5...10 mm2 hard wire without
Tightening torque
Control circuit: 1.7 Nm Screwdriver with bolt Ø 6 flat
Control circuit: 1.7 Nm Screwdriver with No 2 Phillips screw
Power circuit: 2.5 Nm Screwdriver with bolt Ø 6 flat
Power circuit: 2.5 Nm Screwdriver with No 2 Phillips screw
Action time
12...22 ms closed
4...19 ms break
Safety and reliability
B10d = 1369863 Contactors with nominal load compliance in accordance with EN/ISO 13849-1
B10d = 20000000 mechanical load contactors comply with EN/ISO 13849-1
Mechanical life
15 kA2.s
Maximum operating frequency
3600 times / hour on ... <60 °C
Additional information
Surge suppression module
No built-in surge suppression module
Control voltage limit
Release: 0.3...0.6 Uc on 50/60 Hz 60 °C)
Operation: 0.8...1.1 Uc on 50 Hz 60 °C)
Operation: 0.85...1.1 Uc on ... 60 Hz 60 °C)
(~50Hz pull-in) power consumption (VA)
70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
(~50Hz hold) power consumption (VA)
7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
Heat dissipation
2...3 W on 50/60 Hz
Auxiliary contact type
Type mechanical connection 1 NO + 1 NC in accordance with IEC 60947-5-1
Type mirrored to the main contact state 1 NC in accordance with IEC 60947-4-1
Signal loop frequency
25...400 Hz
Minimum switching current [Imin]
5 mA suitable signal loop
Minimum switching voltage
17 V for signal circuit
No overlap time
1.5 ms between power loss NC and NO contact
1.5 ms between the NC and NO contacts
Insulation resistance
> 10 MΩ for signal circuits
surroundings
IP protection level
IP20 front panel complies with IEC 60529
Protective measures
TH conforms to IEC 60068-2-30
Pollution level
3
Operating temperature
-5...60 °C
Storage ambient temperature
-60...80 °C
Ambient air temperature
-40...70 °C (allowed under Uc)
Working elevation
3000 m without
Refractory and resistant to abnormal high temperatures
850 °C in accordance with IEC 60695-2-1
Flame retardant
V1 complies with UL 94
Shock and vibration resistance
Seismic performance contacts open: 2 gn (5...300 Hz)
Seismic performance contact closure: 4 gn (5...300 Hz)
Impact resistance contact closure: 15 gn (11ms)
Impact resistance contacts open: 8 gn (11ms)
height
85 mm
width
90 mm
depth
92 mm
product weight
0.787 kg