Wuxi Fenigal Science & Technology Co., Ltd
Produsen dan Pemasok Produk Industri & Pencahayaan
Wuxi Fenigal Science & Technology Co., Ltd
Produsen dan Pemasok Produk Industri & Pencahayaan
| Tempat asal: | CINA |
| Nama merek: | Dupont |
| Sertifikasi: | CE |
| Nomor model: | SFP-2860 |
| Dokumen: | Model SFP-2860, SFD 2860, S...80.pdf |
| Kuantitas min Order: | 1 pc |
|---|---|
| Harga: | Dapat dinegosiasikan |
| Kemasan rincian: | Pengepakan Ekspor Standar |
| Waktu pengiriman: | 5- 8 hari kerja |
| Syarat-syarat pembayaran: | Western Union, T/T. |
| Menyediakan kemampuan: | 60000 unit per bulan |
| 2860 rentang aliran modul: | 2.0 - 6.1 m3 /jam | 2860 Area membran rentang aliran modul: | 51 m² |
|---|---|---|---|
| 2860 Modul Diameter pori nominal: | 0,03 μm | 2860 Bahan Modul: | Pvdf |
| Diameter 2860 modul: | 8 inci | 2860 Pengaturan Arah Aliran Modul: | Struktur tekanan eksternal, penyaringan jalan buntu |
| Komponen NAOCL (maks.): | 2.000 mg/L. | Komponen Max Backwash Pressure: | 2.5 bar |
| Komponen Penggunaan Utama: | Perawatan air pengolahan air | Keuntungan: | Akurasi filtrasi tinggi |
| Attribute | Value |
|---|---|
| Membrane Area | 51 m² (549 ft²) |
| Flux Range (25°C) | 40–90 LMH |
| Max TMP | 2.1 bar |
| Flow Rate | 2.0–6.9 m³/hr |
| Weight (Empty) | 48kg |
| Target Applications | Industrial wastewater reuse, Seawater pretreatment for desalination, Compact containerized plants, Cooling tower blowdown recovery |
| Parameter | SI Units | US Units |
|---|---|---|
| Filtrate Flux @ 25ºC | 40-120 l/m2/hr | 24-70 gfd |
| Flow range | 2.0 - 6.1 m3/hr | 9.2 - 26.7 gpm |
| Temperature | 1-40ºC | 34-104ºF |
| Max. inlet module pressure (@ 20ºC) | 6.25 bar | 93.75 psi |
| Max. operating TMP | 2.1 bar | 30 psi |
| Max operating air scour flow | 12 nm3/hr | 7.1 scfm |
| Max backwash pressure | 2.5 bar | 36 psi |
| Operating pH | 2-11 | |
Proper start-up of a UF system is indispensable for preparing the membranes for operational service and preventing membrane damage. Adhering to the correct start-up sequence also contributes to ensuring that the operating parameters of the system conform to the design specifications.
Before commencing the system start-up procedures, membrane pretreatment, installation of the membrane modules, instrument calibration, and other system checks should be accomplished. Kindly refer to the product technical manual.
Kontak Person: Mr. Harry
Tel: +86-13646187144